Preliminary Characterization and In Vivo Studies of Structurally Identical (18)F- and (125)I-Labeled Benzyloxybenzenes for PET/SPECT Imaging of β-Amyloid Plaques.

TitlePreliminary Characterization and In Vivo Studies of Structurally Identical (18)F- and (125)I-Labeled Benzyloxybenzenes for PET/SPECT Imaging of β-Amyloid Plaques.
Publication TypeJournal Article
Year of Publication2015
AuthorsYang Y, Zhang X, Cui M, Zhang J, Guo Z, Li Y, Zhang X, Dai J, Liu B
JournalSci Rep
Volume5
Pagination12084
Date Published2015 Jul 14
ISSN2045-2322
KeywordsAlzheimer Disease, Amyloid beta-Peptides, Animals, Brain, Fluorine Radioisotopes, Hydrophobic and Hydrophilic Interactions, Iodine Radioisotopes, Mice, Models, Molecular, Plaque, Amyloid, Positron-Emission Tomography, Protein Aggregates, Protein Aggregation, Pathological, Protein Conformation, Radiopharmaceuticals, Tomography, Emission-Computed, Single-Photon, Tomography, X-Ray Computed
Abstract

With the assistance of molecular docking and 3D-QSAR models established previously, structurally identical (18)F- and (125)I-labeled benzyloxybenzene derivatives were designed to achieve the early detection of Aβ plaques by PET/SPECT imaging. In competition binding assay, ligands 7a and 12a displayed high binding affinities to Aβ42 aggregates with Ki values of 19.5 nM and 23.9 nM, respectively. Specific plaque labeling was observed on the in vitro autoradiography of brain sections from AD patients and Tg mice. In biodistribution, [(125)I]7a, [(18)F]7a, [(125)I]12a and [(18)F]12a all exhibited high initial brain uptakes (>5% ID/g at 2 min). [(125)I]7a and [(125)I]12a cleared fast from the normal brain regions, while corresponding [(18)F]7a and [(18)F]12a showed slow washout rates. Dynamic microPET/CT and microSPECT/CT imaging data in normal ICR mice were in accordance with in vivo biodistribution results. In vivo metabolism results indicated that the different clearance profiles between the structurally identical (18)F- and (125)I-labeled tracers could be attributed to different biochemical characteristics of the radiometabolites. Radioiodinated benzyloxybenzene derivatives exhibited good in vivo biostability in brain. Ex vivo autoradiography further confirmed the strong in vivo Aβ labeling ability of [(125)I]7a. These new fluorinated and iodinated benzyloxybenzenes can develop into PET/SPECT dual imaging agents targeting Aβ plaques.

DOI10.1038/srep12084
Alternate JournalSci Rep
PubMed ID26170205
PubMed Central IDPMC4501006
Related Institute: 
Molecular Imaging Innovations Institute (MI3)

Weill Cornell Medicine
Department of Radiology
525 East 68th Street New York, NY 10065