Title | Cerebral metabolic rate of oxygen (CMRO ) mapping with hyperventilation challenge using quantitative susceptibility mapping (QSM). |
Publication Type | Journal Article |
Year of Publication | 2017 |
Authors | Zhang J, Zhou D, Nguyen TD, Spincemaille P, Gupta A, Wang Y |
Journal | Magn Reson Med |
Volume | 77 |
Issue | 5 |
Pagination | 1762-1773 |
Date Published | 2017 05 |
ISSN | 1522-2594 |
Keywords | Administration, Oral, Adult, Brain, Caffeine, Computer Simulation, Female, Gray Matter, Healthy Volunteers, Humans, Hyperventilation, Image Processing, Computer-Assisted, Imaging, Three-Dimensional, Magnetic Resonance Imaging, Male, Middle Aged, Oxygen, Oxygen Consumption, Reproducibility of Results, Signal-To-Noise Ratio, Spin Labels, Vasoconstriction, Young Adult |
Abstract | PURPOSE: Our objective was to demonstrate the feasibility of using hyperventilation as an efficient vasoconstrictive challenge and prior knowledge as denoising constraints for cerebral metabolic rate of oxygen (CMRO ) mapping based upon quantitative susceptibility mapping (QSM). METHODS: Three-dimensional (3D) multi-echo gradient echo and arterial spin labeling imaging were performed to calculate QSM and perfusion maps before and after a hyperventilation challenge in 11 healthy subjects. For comparison, this was repeated using a caffeine challenge. Whole-brain CMRO and oxygen extraction fraction (OEF) maps were computed using constrained optimization. Hyperventilation scans were repeated to measure reproducibility. Regional agreement of CMRO and OEF maps was analyzed within the cortical gray matter (CGM) using t-test and Bland-Altman plots. RESULTS: Hyperventilation challenge eliminates the 30-min waiting time needed for caffeine to exert its vasoconstrictive effects. Mean CMRO (in µmol/100g/min) obtained in CGM using the caffeine and repeated hyperventilation scans were 149 ± 16, 153 ± 19, and 150 ± 20, respectively. This corresponded to an OEF of 33.6 ± 3.4%, 32.3 ± 3.2%, and 34.1 ± 3.8% at baseline state and 39.8 ± 4.8%, 43.6 ± 6.2%, and 42.8 ± 6.8% at challenged state, respectively. Hyperventilation scans produced a good agreement of CMRO and OEF values. CONCLUSIONS: Hyperventilation is a feasible, reproducible, and efficient vasoconstrictive challenge for QSM-based quantitative CMRO mapping. Magn Reson Med 77:1762-1773, 2017. © 2016 International Society for Magnetic Resonance in Medicine. |
DOI | 10.1002/mrm.26253 |
Alternate Journal | Magn Reson Med |
PubMed ID | 27120518 |
Related Institute:
MRI Research Institute (MRIRI)