Title | Quantitative transport mapping (QTM) of the kidney with an approximate microvascular network. |
Publication Type | Journal Article |
Year of Publication | 2021 |
Authors | Zhou L, Zhang Q, Spincemaille P, Nguyen TD, Morgan J, Dai W, Li Y, Gupta A, Prince MR, Wang Y |
Journal | Magn Reson Med |
Volume | 85 |
Issue | 4 |
Pagination | 2247-2262 |
Date Published | 2021 04 |
ISSN | 1522-2594 |
Keywords | Humans, Kidney, Magnetic Resonance Imaging, Microvessels, Renal Circulation, Spin Labels |
Abstract | PURPOSE: Proof-of-concept study of mapping renal blood flow vector field according to the inverse solution to a mass transport model of time resolved tracer-labeled MRI data. THEORY AND METHODS: To determine tissue perfusion according to the underlying physics of spatiotemporal tracer concentration variation, the mass transport equation is integrated over a voxel with an approximate microvascular network for fitting time-resolved tracer imaging data. The inverse solution to the voxelized transport equation provides the blood flow vector field, which is referred to as quantitative transport mapping (QTM). A numerical microvascular network modeling the kidney with computational fluid dynamics reference was used to verify the accuracy of QTM and the current Kety's method that uses a global arterial input function. Multiple post-label delay arterial spin labeling (ASL) of the kidney on seven subjects was used to assess QTM in vivo feasibility. RESULTS: Against the ground truth in the numerical model, the error in flow estimated by QTM (18.6%) was smaller than that in Kety's method (45.7%, 2.5-fold reduction). The in vivo kidney perfusion quantification by QTM (cortex: 443 ± 58 mL/100 g/min and medulla: 190 ± 90 mL/100 g/min) was in the range of that by Kety's method (482 ± 51 mL/100 g/min in the cortex and 242 ± 73 mL/100 g/min in the medulla), and QTM provided better flow homogeneity in the cortex region. CONCLUSIONS: QTM flow velocity mapping is feasible from multi-delay ASL MRI data based on inverting the transport equation. In a numerical simulation, QTM with deconvolution in space and time provided more accurate perfusion quantification than Kety's method with deconvolution in time only. |
DOI | 10.1002/mrm.28584 |
Alternate Journal | Magn Reson Med |
PubMed ID | 33210310 |
PubMed Central ID | PMC7839791 |
Grant List | R01 AG057848 / AG / NIA NIH HHS / United States R01 NS105144 / NS / NINDS NIH HHS / United States R01 NS095562 / NS / NINDS NIH HHS / United States R01 NS090464 / NS / NINDS NIH HHS / United States R01 CA181566 / CA / NCI NIH HHS / United States R01 CA178007 / CA / NCI NIH HHS / United States |
Related Institute:
MRI Research Institute (MRIRI) Brain Health Imaging Institute (BHII)