Magnetic resonance quantitative susceptibility mapping in the evaluation of hepatic fibrosis in chronic liver disease: a feasibility study.

TitleMagnetic resonance quantitative susceptibility mapping in the evaluation of hepatic fibrosis in chronic liver disease: a feasibility study.
Publication TypeJournal Article
Year of Publication2021
AuthorsQu Z, Yang S, Xing F, Tong R, Yang C, Guo R, Huang J, Lu F, Fu C, Yan X, Hectors S, Gillen K, Wang Y, Liu C, Zhan S, Li J
JournalQuant Imaging Med Surg
Volume11
Issue4
Pagination1170-1183
Date Published2021 Apr
ISSN2223-4292
Abstract

Background: Noninvasive methods for the early diagnosis and staging of hepatic fibrosis are needed. The present study aimed to investigate the alteration of magnetic susceptibility in the liver of patients with various fibrosis stages and to evaluate the feasibility of using susceptibility to stage hepatic fibrosis.

Methods: A total of 30 consecutive patients with chronic liver diseases (CLDs) underwent magnetic resonance imaging (MRI) and liver biopsy evaluation of hepatic fibrosis, necroinflammatory activity, iron load, and steatosis. Quantitative susceptibility mapping (QSM), R2* and proton density fat fraction (PDFF) images were postprocessed from the same gradient-echo data for quantitative tissue characterization using region of interest (ROI) analysis. The differences for MRI measurements between cohorts of non-significant (Ishak-F <3) and significant fibrosis (Ishak-F ≥3) and the correlation of MRI measurements with fibrosis stages and necroinflammatory activity grades were tested. Receiver operating characteristic (ROC) analysis was also performed.

Results: There was a significant difference in liver susceptibility between the cohorts of significant and non-significant fibrosis (Z=-2.880, P=0.004). A moderate negative correlation between the stages of liver fibrosis and liver susceptibility was observed (r=-0.471, P=0.015). Liver magnetic susceptibility differentiated non-significant from significant hepatic fibrosis with an area under the receiver operating curve (AUC) of 0.836 (P=0.004). A highly sensitive diagnostic performance with an AUC of 0.933 was obtained using magnetic susceptibility and PDFF together (P<0.001).

Conclusions: A noninvasive liver QSM-based evaluation promises an accurate assessment of significant fibrosis in patients with CLDs.

DOI10.21037/qims-20-720
Alternate JournalQuant Imaging Med Surg
PubMed ID33816158
PubMed Central IDPMC7930689
Related Institute: 
MRI Research Institute (MRIRI)

Weill Cornell Medicine
Department of Radiology
525 East 68th Street New York, NY 10065