Imaging markers for Alzheimer disease: which vs how.

TitleImaging markers for Alzheimer disease: which vs how.
Publication TypeJournal Article
Year of Publication2013
AuthorsFrisoni GB, Bocchetta M, Chételat G, Rabinovici GD, de Leon MJ, Kaye J, Reiman EM, Scheltens P, Barkhof F, Black SE, Brooks DJ, Carrillo MC, Fox NC, Herholz K, Nordberg A, Jack CR, Jagust WJ, Johnson KA, Rowe CC, Sperling RA, Thies W, Wahlund L-O, Weiner MW, Pasqualetti P, DeCarli C
Corporate AuthorsISTAART's NeuroImaging Professional Interest Area
JournalNeurology
Volume81
Issue5
Pagination487-500
Date Published2013 Jul 30
ISSN1526-632X
KeywordsAlzheimer Disease, Biomarkers, Fluorodeoxyglucose F18, Humans, Magnetic Resonance Imaging, Radiography, Tomography, Emission-Computed, Single-Photon
Abstract

Revised diagnostic criteria for Alzheimer disease (AD) acknowledge a key role of imaging biomarkers for early diagnosis. Diagnostic accuracy depends on which marker (i.e., amyloid imaging, ¹⁸F-fluorodeoxyglucose [FDG]-PET, SPECT, MRI) as well as how it is measured ("metric": visual, manual, semiautomated, or automated segmentation/computation). We evaluated diagnostic accuracy of marker vs metric in separating AD from healthy and prognostic accuracy to predict progression in mild cognitive impairment. The outcome measure was positive (negative) likelihood ratio, LR+ (LR-), defined as the ratio between the probability of positive (negative) test outcome in patients and the probability of positive (negative) test outcome in healthy controls. Diagnostic LR+ of markers was between 4.4 and 9.4 and LR- between 0.25 and 0.08, whereas prognostic LR+ and LR- were between 1.7 and 7.5, and 0.50 and 0.11, respectively. Within metrics, LRs varied up to 100-fold: LR+ from approximately 1 to 100; LR- from approximately 1.00 to 0.01. Markers accounted for 11% and 18% of diagnostic and prognostic variance of LR+ and 16% and 24% of LR-. Across all markers, metrics accounted for an equal or larger amount of variance than markers: 13% and 62% of diagnostic and prognostic variance of LR+, and 29% and 18% of LR-. Within markers, the largest proportion of diagnostic LR+ and LR- variability was within ¹⁸F-FDG-PET and MRI metrics, respectively. Diagnostic and prognostic accuracy of imaging AD biomarkers is at least as dependent on how the biomarker is measured as on the biomarker itself. Standard operating procedures are key to biomarker use in the clinical routine and drug trials.

DOI10.1212/WNL.0b013e31829d86e8
Alternate JournalNeurology
PubMed ID23897875
PubMed Central IDPMC3776529
Grant ListG0601846 / MRC_ / Medical Research Council / United Kingdom
G0801306 / MRC_ / Medical Research Council / United Kingdom
P30 AG008051 / AG / NIA NIH HHS / United States
R01 AG012101 / AG / NIA NIH HHS / United States
Related Institute: 
Brain Health Imaging Institute (BHII)

Weill Cornell Medicine
Department of Radiology
525 East 68th Street New York, NY 10065