A fast, noniterative approach for accelerated high-temporal resolution cine-CMR using dynamically interleaved streak removal in the power-spectral encoded domain with low-pass filtering (DISPEL) and modulo-prime spokes (MoPS).

TitleA fast, noniterative approach for accelerated high-temporal resolution cine-CMR using dynamically interleaved streak removal in the power-spectral encoded domain with low-pass filtering (DISPEL) and modulo-prime spokes (MoPS).
Publication TypeJournal Article
Year of Publication2017
AuthorsKawaji K, Patel MB, Cantrell CG, Tanaka A, Marino M, Tamura S, Wang H, Wang Y, Carroll TJ, Ota T, Patel AR
JournalMed Phys
Volume44
Issue7
Pagination3450-3463
Date Published2017 Jul
ISSN2473-4209
KeywordsAlgorithms, Artifacts, Heart, Humans, Image Interpretation, Computer-Assisted, Magnetic Resonance Imaging, Cine, Reproducibility of Results
Abstract

PURPOSE: To introduce a pair of accelerated non-Cartesian acquisition principles that when combined, exploit the periodicity of k-space acquisition, and thereby enable acquisition of high-temporal cine Cardiac Magnetic Resonance (CMR).

METHODS: The mathematical formulation of a noniterative, undersampled non-Cartesian cine acquisition and reconstruction is presented. First, a low-pass filtering step that exploits streaking artifact redundancy is provided (i.e., Dynamically Interleaved Streak removal in the Power-spectrum Encoded domain with Low-pass filtering [DISPEL]). Next, an effective radial acquisition for the DISPEL approach that exploits the property of prime numbers is described (i.e., Modulo-Prime Spoke [MoPS]). Both DISPEL and MoPS are examined using numerical simulation of a digital heart phantom to show that high-temporal cine-CMR is feasible without removing physiologic motion vs aperiodic interleaving using Golden Angles. The combined high-temporal cine approach is next examined in 11 healthy subjects for a time-volume curve assessment of left ventricular systolic and diastolic performance vs conventional Cartesian cine-CMR reference.

RESULTS: The DISPEL method was first shown using simulation under different streak cycles to allow separation of undersampled radial streaking artifacts from physiologic motion with a sufficiently frequent streak-cycle interval. Radial interleaving with MoPS is next shown to allow interleaves with pseudo-Golden-Angle variants, and be more compatible with DISPEL against irrational and nonperiodic rotation angles, including the Golden-Angle-derived rotations. In the in vivo data, the proposed method showed no statistical difference in the systolic performance, while diastolic parameters sensitive to the cine's temporal resolution were statistically significant (P < 0.05 vs Cartesian cine).

CONCLUSIONS: We demonstrate a high-temporal resolution cine-CMR using DISPEL and MoPS, whose streaking artifact was separated from physiologic motion.

DOI10.1002/mp.12234
Alternate JournalMed Phys
PubMed ID28339110
PubMed Central IDPMC5976238
Grant List14PRE20380810 / AHA_ / American Heart Association-American Stroke Association / United States
UL1 TR000430 / TR / NCATS NIH HHS / United States
Related Institute: 
MRI Research Institute (MRIRI)

Weill Cornell Medicine
Department of Radiology
525 East 68th Street New York, NY 10065