Assessment of metastatic lymph nodes in head and neck squamous cell carcinomas using simultaneous F-FDG-PET and MRI.

TitleAssessment of metastatic lymph nodes in head and neck squamous cell carcinomas using simultaneous F-FDG-PET and MRI.
Publication TypeJournal Article
Year of Publication2020
AuthorsChen J, Hagiwara M, Givi B, Schmidt B, Liu C, Chen Q, Logan J, Mikheev A, Rusinek H, Kim SGene
JournalSci Rep
Volume10
Issue1
Pagination20764
Date Published2020 11 27
ISSN2045-2322
KeywordsAdult, Aged, Aged, 80 and over, Female, Fluorodeoxyglucose F18, Follow-Up Studies, Head and Neck Neoplasms, Humans, Lymph Nodes, Lymphatic Metastasis, Magnetic Resonance Imaging, Male, Middle Aged, Positron-Emission Tomography, Prognosis, Radiopharmaceuticals, Squamous Cell Carcinoma of Head and Neck
Abstract

In this study, we investigate the feasibility of using dynamic contrast enhanced magnetic resonance imaging (DCE-MRI), diffusion weighted imaging (DWI), and dynamic positron emission tomography (PET) for detection of metastatic lymph nodes in head and neck squamous cell carcinoma (HNSCC) cases. Twenty HNSCC patients scheduled for lymph node dissection underwent DCE-MRI, dynamic PET, and DWI using a PET-MR scanner within one week prior to their planned surgery. During surgery, resected nodes were labeled to identify their nodal levels and sent for routine clinical pathology evaluation. Quantitative parameters of metastatic and normal nodes were calculated from DCE-MRI (v, v, PS, F, K), DWI (ADC) and PET (K, K, k, k) to assess if an individual or a combination of parameters can classify normal and metastatic lymph nodes accurately. There were 38 normal and 11 metastatic nodes covered by all three imaging methods and confirmed by pathology. 34% of all normal nodes had volumes greater than or equal to the smallest metastatic node while 4 normal nodes had SUV > 4.5. Among the MRI parameters, the median v, F, PS, and K values of the metastatic lymph nodes were significantly lower (p = <0.05) than those of normal nodes. v and ADC did not show any statistical significance. For the dynamic PET parameters, the metastatic nodes had significantly higher k (p value = 8.8 × 10) and K (p value = 5.3 × 10) than normal nodes. K and k did not show any statistically significant difference. K had the best separation with accuracy = 0.96 (sensitivity = 1, specificity = 0.95) using a cutoff of K = 5.3 × 10 mL/cm/min, while k and volume had accuracy of 0.94 (sensitivity = 0.82, specificity = 0.97) and 0.90 (sensitivity = 0.64, specificity = 0.97) respectively. 100% accuracy can be achieved using a multivariate logistic regression model of MRI parameters after thresholding the data with K < 5.3 × 10 mL/cm/min. The results of this preliminary study suggest that quantitative MRI may provide additional value in distinguishing metastatic nodes, particularly among small nodes, when used together with FDG-PET.

DOI10.1038/s41598-020-77740-5
Alternate JournalSci Rep
PubMed ID33247166
PubMed Central IDPMC7695736
Grant ListP30 AG066512 / AG / NIA NIH HHS / United States
U24 EB028980 / EB / NIBIB NIH HHS / United States
R21CA188217 / NH / NIH HHS / United States
R21 CA188217 / CA / NCI NIH HHS / United States
UG3 CA228699 / CA / NCI NIH HHS / United States
R01 CA160620 / CA / NCI NIH HHS / United States
P41 EB017183 / EB / NIBIB NIH HHS / United States
Related Institute: 
MRI Research Institute (MRIRI)

Weill Cornell Medicine
Department of Radiology
525 East 68th Street New York, NY 10065