The appearance of magnetic susceptibility objects in SWI phase depends on object size: Comparison with QSM and CT.

TitleThe appearance of magnetic susceptibility objects in SWI phase depends on object size: Comparison with QSM and CT.
Publication TypeJournal Article
Year of Publication2022
AuthorsXie H, Zhuang H, Guo Y, Sharma RD, Zhang Q, Li J, Lu S, Xu L, Chan Q, Yoneda T, Spincemaille P, Zhang H, Guo H, Prince MR, Yu C, Wang Y
JournalClin Imaging
Volume82
Pagination67-72
Date Published2022 Feb
ISSN1873-4499
KeywordsBrain, Brain Mapping, Humans, Magnetic Resonance Imaging, Tomography, X-Ray Computed, White Matter
Abstract

PURPOSE: Tissue magnetic susceptibility sign can potentially be detected on susceptibility weighted imaging (SWI) phase (SW-P). This study aims to investigate its performance for depicting brain susceptibility structures.

METHODS: A simulation was performed to depict magnetic susceptibility structures of various geometries on SW-P and quantitative susceptibility mapping (QSM). Brain MRI was performed on 25 subjects using SWI on a 3 T MRI system. QSM was generated from the same data. SW-P and QSM were analyzed according to radiological assessment for depicting globus pallidus nuclei, optic radiation white matter tracts, and lateral ventricular choroid plexus calcifications. In 11 of these subjects, CT was available and correlated with SW-P and QSM to assess their performance in quantifying calcifications in the choroid plexus.

RESULTS: In simulation, the appearance of a sphere on SW-P ranged from centric nodule to mixed positive and negative values as the diameter increased. Large cylinders also appeared as mixed positive and negative values. In comparison, QSM correctly depicted the susceptibility distribution of all magnetic structures. On human brain images, SW-P depicted the globus pallidus and optic radiation with mixed positive and negative values, consistent with simulation, and small choroid plexus calcifications as either mixed positive and negative values or as centric nodules; QSM depicted all structures as solid structures with the expected signs. For measuring calcification in the choroid plexus, QSM vs CT linear regression had a higher coefficient of determination compared to SW-P vs CT and SW-P vs QSM.

CONCLUSION: Appearance of susceptibility sources on SW-P changes with object size. This problem can be overcome using QSM.