Found 41 results
Filters: Keyword is Cerebrovascular Circulation  [Clear All Filters]
2023
Zhang Q, Sui C, Cho J, Yang L, Chen T, Guo B, Gillen KMcCabe, Li J, Guo L, Wang Y.  2023.  Assessing Cerebral Oxygen Metabolism Changes in Patients With Preeclampsia Using Voxel-Based Morphometry of Oxygen Extraction Fraction Maps in Magnetic Resonance Imaging.. Korean J Radiol. 24(4):324-337.
Zhuang H, Cho J, Chiang GChia-Yi, Kovanlikaya I, Heier LAnne, Dyke JP, Wang Y.  2023.  Cerebral oxygen extraction fraction declines with ventricular enlargement in patients with normal pressure hydrocephalus.. Clin Imaging. 97:22-27.
Taso M, Aramendía-Vidaurreta V, Englund EK, Francis S, Franklin S, Madhuranthakam AJ, Martirosian P, Nayak KS, Qin Q, Shao X et al..  2023.  Update on state-of-the-art for arterial spin labeling (ASL) human perfusion imaging outside of the brain.. Magn Reson Med. 89(5):1754-1776.
2022
Cho J, Nguyen TD, Huang W, Sweeney EM, Luo X, Kovanlikaya I, Zhang S, Gillen KM, Spincemaille P, Gupta A et al..  2022.  Brain oxygen extraction fraction mapping in patients with multiple sclerosis.. J Cereb Blood Flow Metab. 42(2):338-348.
Cho J, Zhang J, Spincemaille P, Zhang H, Hubertus S, Wen Y, Jafari R, Zhang S, Nguyen TD, Dimov AV et al..  2022.  QQ-NET - using deep learning to solve quantitative susceptibility mapping and quantitative blood oxygen level dependent magnitude (QSM+qBOLD or QQ) based oxygen extraction fraction (OEF) mapping.. Magn Reson Med. 87(3):1583-1594.
2021
Cho J, Ma Y, Spincemaille P, Pike GBruce, Wang Y.  2021.  Cerebral oxygen extraction fraction: Comparison of dual-gas challenge calibrated BOLD with CBF and challenge-free gradient echo QSM+qBOLD.. Magn Reson Med. 85(2):953-961.
Cho J, Lee J, An H, Goyal MS, Su Y, Wang Y.  2021.  Cerebral oxygen extraction fraction (OEF): Comparison of challenge-free gradient echo QSM+qBOLD (QQ) with O PET in healthy adults.. J Cereb Blood Flow Metab. 41(7):1658-1668.
Zun Z, Kapse K, Jacobs M, Basu S, Said M, Andersen N, Murnick J, Chang T, Plessis Adu, Limperopoulos C.  2021.  Longitudinal Trajectories of Regional Cerebral Blood Flow in Very Preterm Infants during Third Trimester Ex Utero Development Assessed with MRI.. Radiology. 299(3):691-702.
Cho J, Spincemaille P, Nguyen TD, Gupta A, Wang Y.  2021.  Temporal clustering, tissue composition, and total variation for mapping oxygen extraction fraction using QSM and quantitative BOLD.. Magn Reson Med. 86(5):2635-2646.
Tataryn NM, Singh V, Dyke JP, Berk-Rauch HE, Clausen DM, Aronowitz E, Norris EH, Strickland S, Ahn HJin.  2021.  Vascular endothelial growth factor associated dissimilar cerebrovascular phenotypes in two different mouse models of Alzheimer's Disease.. Neurobiol Aging. 107:96-108.
2020
Ma Y, Sun H, Cho J, Mazerolle EL, Wang Y, G Pike B.  2020.  Cerebral OEF quantification: A comparison study between quantitative susceptibility mapping and dual-gas calibrated BOLD imaging.. Magn Reson Med. 83(1):68-82.
Cho J, Zhang S, Kee Y, Spincemaille P, Nguyen TD, Hubertus S, Gupta A, Wang Y.  2020.  Cluster analysis of time evolution (CAT) for quantitative susceptibility mapping (QSM) and quantitative blood oxygen level-dependent magnitude (qBOLD)-based oxygen extraction fraction (OEF) and cerebral metabolic rate of oxygen (CMRO ) mapping.. Magn Reson Med. 83(3):844-857.
Ma Y, Mazerolle EL, Cho J, Sun H, Wang Y, G Pike B.  2020.  Quantification of brain oxygen extraction fraction using QSM and a hyperoxic challenge.. Magn Reson Med. 84(6):3271-3285.
2019
Glodzik L, Rusinek H, Tsui W, Pirraglia E, Kim H-J, Deshpande A, Li Y, Storey P, Randall C, Chen J et al..  2019.  Different Relationship Between Systolic Blood Pressure and Cerebral Perfusion in Subjects With and Without Hypertension.. Hypertension. 73(1):197-205.
Hubertus S, Thomas S, Cho J, Zhang S, Wang Y, Schad LRudi.  2019.  Using an artificial neural network for fast mapping of the oxygen extraction fraction with combined QSM and quantitative BOLD.. Magn Reson Med. 82(6):2199-2211.
2018
Guo J, Holdsworth SJ, Fan AP, Lebel MR, Zun Z, Shankaranarayanan A, Zaharchuk G.  2018.  Comparing accuracy and reproducibility of sequential and Hadamard-encoded multidelay pseudocontinuous arterial spin labeling for measuring cerebral blood flow and arterial transit time in healthy subjects: A simulation and in vivo study.. J Magn Reson Imaging. 47(4):1119-1132.
Zhang J, Cho J, Zhou D, Nguyen TD, Spincemaille P, Gupta A, Wang Y.  2018.  Quantitative susceptibility mapping-based cerebral metabolic rate of oxygen mapping with minimum local variance.. Magn Reson Med. 79(1):172-179.
Ramos-Cejudo J, Wisniewski T, Marmar C, Zetterberg H, Blennow K, de Leon MJ, Fossati S.  2018.  Traumatic Brain Injury and Alzheimer's Disease: The Cerebrovascular Link.. EBioMedicine. 28:21-30.
2017
Federau C, Christensen S, Zun Z, Park S-W, Ni W, Moseley M, Zaharchuk G.  2017.  Cerebral blood flow, transit time, and apparent diffusion coefficient in moyamoya disease before and after acetazolamide.. Neuroradiology. 59(1):5-12.
Ni WW, Christen T, Rosenberg J, Zun Z, Moseley ME, Zaharchuk G.  2017.  Imaging of cerebrovascular reserve and oxygenation in Moyamoya disease.. J Cereb Blood Flow Metab. 37(4):1213-1222.
Voss HU, Dyke JP, Tabelow K, Schiff ND, Ballon DJ.  2017.  Magnetic resonance advection imaging of cerebrovascular pulse dynamics.. J Cereb Blood Flow Metab. 37(4):1223-1235.
Natelson BH, Mao X, Stegner AJ, Lange G, Vu D, Blate M, Kang G, Soto E, Kapusuz T, Shungu DC.  2017.  Multimodal and simultaneous assessments of brain and spinal fluid abnormalities in chronic fatigue syndrome and the effects of psychiatric comorbidity.. J Neurol Sci. 375:411-416.
2016
Iturria-Medina Y, Sotero RC, Toussaint PJ, Mateos-Pérez JM, Evans AC.  2016.  Early role of vascular dysregulation on late-onset Alzheimer's disease based on multifactorial data-driven analysis.. Nat Commun. 7:11934.
Kudo K, Liu T, Murakami T, Goodwin J, Uwano I, Yamashita F, Higuchi S, Wang Y, Ogasawara K, Ogawa A et al..  2016.  Oxygen extraction fraction measurement using quantitative susceptibility mapping: Comparison with positron emission tomography.. J Cereb Blood Flow Metab. 36(8):1424-33.
2015
Zun Z, Hargreaves BA, Rosenberg J, Zaharchuk G.  2015.  Improved multislice perfusion imaging with velocity-selective arterial spin labeling.. J Magn Reson Imaging. 41(5):1422-31.